Product image coming soon

PIRTEK FIRE ARMOUR BOP & CONTROL LINE ASSEMBLIES

PFA

Brochure ready to generate

Customise your brochure

Choose your local service centre

Its contact details and location map will appear on the final page.

Your details

This is a non-production environment. The notification will be sent to multimedia@digitalink.com.au instead of the selected franchise.

Inner Liner
Seamless synthetic rubber, reistant to oil
Outer Cover
Abrasion resistant stainless steel armour resistant to oils, ozone, and weathering, and fire resistant to Lloyd and API requirements
Ref. Specifications
Spiral hoses meet or exceed SAE J 517 Braided hoses meet or exceed EN857 2SC Tested in accordance with SAE J 517, EN 856, AS 3791 Fire Resistance Compliance: Lloyds OD1000/499 API 16D
Layline Text
No layline
Temperature Range
-40 degrees C up to +100 degrees C / (internal hose): -40 degrees C up to +100 degrees C intermittent to 125 degrees C
Application
Hydraulic control for blowout preventer (BOP) stacks Hydraulic control lines requiring fire resistant capability up to 700 degrees C for 5 minutes.
Group Notes
XX - denotes length of hose assembly in Feet. AVAILABLE END CONFIGURATIONS (STAINLESS STEEL): NPT Male, JIC Female, Hammer Union. Other ends to customer specification can be supplied.