Product image coming soon

OETIKER® 2-EAR CLAMPS

IHCEC

Brochure ready to generate

Customise your brochure

Choose your local service centre

Its contact details and location map will appear on the final page.

Your details

This is a non-production environment. The notification will be sent to multimedia@digitalink.com.au instead of the selected franchise.

Construction
Spiral welded tube cut into rings Post production annealing process removes residual stress De-burred edges reduce hose damage
Assembly Instructions
  • 1. Apply the pincers to one ear (either as pictured above, or from the side using a side pincer tool), and close the tool with sufficient force to draw the lower radii to a 3/4 closed position.
  • 2. Repeat the procedure on the second ear, this time closing until obvious hose compression is evident.
  • 3. Pinch the first ear a second time until both clamp ears appear to be sharing the compression load equally as evidenced by symmetrical 'Omega' shaped formations.
Material
Steel
Application
  • Fast, simple and secure installation
  • Visual indication of proper closure Ideal for air and liquid lines at low to medium pressures 2-ear design provides good coupling range to suit thick walled hoses
  • Can absorb thermal expansion and vibration